3 process controller, 1 process controller application example, 0v 10v – NORD Drivesystems BU0750 User Manual

Page 146

Advertising
background image

NORDAC SK 750E Manual

146

Subject to technical amendments

BU 0750 GB-3311

10.3 Process controller

The process controller is a PI controller which can be used to limit the controller output. In addition, the output
is scaled as a percentage of a master setpoint. This provides the option of controlling any downstream drives
with the master setpoint and readjusting using the PI controller.

+

-

+

X

x1

x2

y

x1*x2

100 %

y=

100 %

0-100 %

+

Master setpoint

a) Analog input

(P400=4)

b) Analog function

for DIG IN (=28)

Setpoint

a) Analog function

for DIG IN (=41)

b) Analog input

(P400=15)

c) P412 (0.0-10.0V)

Actual value

a) Analog function

for DIG IN (=40)

b) Analog input

(P400=14)

P factor P413
I factor P414

Limitation P415

Internal value for calculation

Start-up time P102

Analog func. for
dig. input
Func. 42

PI controller

Setpoint ramp

Setpoint ramp

Ramp PID controller
P416


Fig.: Process controller flow diagram


10.3.1 Process controller application example


M

M

M

M

0V

10V



AIN 1 / AIN 2

DIG IN 1

DIG IN 2

Setpoint of pilot machine

Enabled right

Nominal position CR
via parameter P412

Actual position CR

Frequency inverter

f

t

Setpoint of
pilot machine

Controller
limit P415 in
% of setpoint

Controller
limit P415

Controlled drive via CR

Compensating roller = CR (dancer roller)

Pilot machine

Actual

CR position

via

Poti 0 -10V

Centre 5V
nominal
position

Advertising