6. Electrical installation

Festo.P.BE-CMMS-ST-G2-HW-EN 1008NH

109

Pin

Name

Value

Mode = 3 - Synchronisation

13

DOUT3

24 V 100 mA Output freely programmable - default error (low active)

14

AGND

0 V

Reference potential for the analogue signals

15

DIN13

Stop input (low active)

16 DIN11

17

AMON0

0...10 V ±4% Analogue monitor output 0

18

+ 24 V

24 V 100 mA 24 V supply carried out

19 DIN0

20

DIN2

24 V

Pulse_24 / CW

21

DIN4

End stage enable (high active)

22

DIN6

Limit switch 0

23

DIN8

Start synchronisation

24

DOUT0

24 V 100 mA Ready for operation output (high active)

25

DOUT2

24 V 100 mA Setpoint reached output (high active)

Table

6.5 Pin allocation: I/O interface [X1] Mode 3

6.4.2 Increment generator input [X2]

Pin Name

Value

Specification

1

A+

5 V, Ri = 120 Ohm

Increment generator signal A, positive polarity

2

B+

5 V, Ri = 120 Ohm

Increment generator signal B, positive polarity

3

N+

5 V, Ri = 120 Ohm

Increment generator zero pulse N, positive polarity

4

GND

-

Reference GND for the encoder

5

VCC

+5 V +-5% 100 mA

Auxiliary supply, max. load 100 mA, short-circuit
proof.

6 A-

5 V, Ri = 120 Ohm

Increment generator signal A, negative polarity

7

B-

5 V, Ri = 120 Ohm

Increment generator signal B, negative polarity

8

N-

5 V, Ri = 120 Ohm

Increment generator zero pulse N, negative polarity

9

GND

-

Internal screen for the connecting cable

Table

6.6 Pin allocation: Increment generator input [X2]