Error message
Main
index

Sub-
index

Meaning of error
message

Measures Error

reaction

8

Fault: record chaining,
unknown command

Unknown command found during record
chaining.

41

9

Route program jump
target error

Jump to a positioning record outside the
permitted range.

PS off

1)

1

Positioning: Error in pre-
calculation

The positioning target cannot be reached
due to the positioning options or the
parameters.
Check the parameterisation of the affected
positioning records.

PS off

1)

4 Homing

required

No positioning possible without homing.
Homing must be carried out.

Warn

1)

42

9

Position data record error Common error:

1. An attempt is being made to start an
unknown or deactivated position record.
2. The set acceleration is too small for the
maximum velocity permitted. (Risk of
computational overrun in trajectory
calculation)

PS off

0

Limit switch error

Negative hardware limit switch reached.
Check parameters, wiring and limit
switches.

1

Limit switch error

Positive hardware limit switch reached.
Check parameters, wiring and limit
switches.

43

9

Limit switch error

Both hardware limit switches active at the
same time.
Check parameters, wiring and limit
switches.

Warn

1)

0

Driver supply fault

The driver supply is still active despite
"safe standstill".

PS off

1

Driver supply fault

The driver supply was re-applied even
though "safe standstill" was still active.

PS off

2

Driver supply fault

The driver supply is not re-applied even
though the "safe standstill" signal is no
longer active.

PS off

45

3

Plausibility error DIN 4

Error during plausibility check of output
stage enable.

PS off

1

DeviceNet communication
error

The 24V bus voltage is missing

PS off

1)

64

2 DeviceNet

communication

error

Receive buffer overflow

PS off

1)