2 error messages, Error messages – Festo Контроллеры двигателя CMMS-ST User Manual

Page 122

Advertising
background image

8. Service functions and error messages

122

Festo.P.BE-CMMS-ST-G2-HW-EN

1008NH

Display Meaning

PH x

Homing run. “x” represents the respective phase of the homing run:
0: Search phase
1: Slow moving phase
2: Travel to zero position
The digits are sequentially displayed

E xxy

Error message with index “xx” and sub-index “y”

-xxy-

Warning message with index “xx” and sub-index “y”. Warnings are shown at least
twice on the seven-segment display.

Table

8.1 Operating mode and error display

8.2.2 Error messages

When a fault occurs, the CMMS-ST displays an error message cyclically in the seven
segment display. The error message consists of an E (for error), a main index and sub-
index, e.g.: E 01 0.
The meaning and the measures for the error messages are compiled in the table below:

Error message
Main
index

Sub-
index

Meaning of error
message

Measures Error

reaction

01

0

Stack overflow

Wrong firmware?
Reload standard firmware if necessary.
Contact Technical Support.

PS off

02 0 Undervoltage

in intermediate circuit

Undervoltage monitoring is configured
using the FCT.
Measure intermediate circuit voltage.
Check configuration.

PS off

1)

0 Motor

temperature

monitoring

Motor too hot?
Check parameters (current regulator,
current limits)
Correct sensor?
Cable broken?
Sensor defective?
If the error remains even when the sensor
is bridged: device defective.

PS off

03

1 Motor

temperature

monitoring

Fault in dig. motor temperature sensor

PS off

1)

04 0 Over-/under-temperature

in power electronics

Temperature display plausible?
Check installation conditions (cooling: via
the housing surface, the integrated heat
sink and back wall).

PS off

1)

Advertising