9 trajectory generator, Trajectory generator – Festo Контроллеры двигателя CMMS-ST User Manual

Page 59

Advertising
background image

3. Product description

Festo.P.BE-CMMS-ST-G2-HW-EN 1008NH

59

Controller

release

START

1

0

1

0

1

0

1

0

1

0

1

0

1

0

Limit switch E0

1

0

DOUT0: READY

DOUT1: MC

DOUT2: ACK

DOUT3: ERROR

Statusword:

referenced

1

Limit switch E1

0

1

0

STOP

1

0

t1

t1

t1

tx

tx

tx

tx

Drive is moving

+

t1

= 1.6 ms

tx

= x ms (dependent on ramps)

Fig.

3.6 Signal sequence with interruption through STOP input

3.5.9 Trajectory generator

For a start signal for a positioning record via DIN8, fieldbus or RS232 interface, the
selected positioning record is loaded to the trajectory generator.
Based on the data record loaded, a necessary internal pre-calculation is made. The pre-
calculations can take from 1.6 to 5 ms. The following configurable options are available
for processing the start signal.
- After a start signal is detected during a current positioning run, the run continues to

the target position.

- After a start signal is detected, positioning is cancelled and the drive runs at a

constant speed. After pre-calculation is completed, the drive runs to the new target
position.

The trajectory generator sends the following messages:
- Target reached, (Default: digital output DOUT1 – MC)
- Remaining distance reached.
-

Advertising