Setting the operating mode

Due to a necessary synchronisation of internal processes, the change of operation mode
can require some cycle times of the controller. We therefore recommend that you always
verify and wait for reception of the desired operation mode.

Operating mode

Syntax

Response

Regulating torque

OW:0030:00000004

Speed adjustment

OW:0030:00000008

Positioning

OW:0030:00000002

OK! or OW:EEEEEEEE

Table

3.12 Operating mode

Faulty return values can be called up due to invalid values that do not come from the
above-named group. The current operation mode can be read by using the “OR”
command.

Control via RS-485

Note
Before activating the RS-485 interface, please make sure that you
are using a completely wired null modem cable. All pins of the
cable must be occupied according to the following specification
(also see chapter 6.4.5).


Pin Brief

description

Name Signal

direction

Description

1 DCD

Data

carrier

detect

Transfer device -->
end device

Data carrier signal was recorded by
transfer device.

2

RxD

Receive (x) Data

Transfer device -->
end device

Line at the end device that receives a
data bit from the transfer device.

3

TxD

Transmit (x) Data

End device -->
Transfer device

Line at the end device that sends a data
bit to the transfer device.

4 DTR

Data

terminal

ready

End device -->
Transfer device

End device is ready for use.

5

GND

Ground (earth)

None

Reference potential at 0 V.

6

DSR

Data set ready

Transfer device -->
end device

Transfer device is ready for use.

7

RTS

Request to send

End device -->
Transfer device

End device displays that the remote
station should send (send request).

8

CTS

Clear to send

Transfer device -->
end device

Transfer device shows reception
readiness (send permission).