10 i/o sequence control, I/o sequence control – Festo Контроллеры двигателя CMMS-ST User Manual

Page 60

Advertising
background image

3. Product description

60

Festo.P.BE-CMMS-ST-G2-HW-EN

1008NH

3.5.10 I/O sequence control

T

Transition condition

Actions of the user

T1

RESET / Power ON

T2

Time out has expired or the firmware download is
complete.

T3

The initialisation has been carried out successfully.

T4

DIN4=1 and DIN5=1

T5

“Torque control” was selected in the commissioning
software.

Setpoint specification via AIN0/AGND

T22

T25

T24

T23

T20

T21

T18

T19

T17

T16

T15

T13

T12

T10 T11

T9

T8

T6

T5

T4

T3

T2

T1

RESET
Power ON

Boot program

Firmware
download

Initialisation

Ready for
operation


Initialise SD card

Load/save SD card
parameters

From all except
RESET / Power ON

Error condition

Acknowledge error

Activate
output stage




Regulating torque

Speed adjustment

Position control

Jog mode

Homing

Deactivate
output stage