Festo Контроллеры двигателя CMMS-ST User Manual

Page 126

Advertising
background image

8. Service functions and error messages

126

Festo.P.BE-CMMS-ST-G2-HW-EN

1008NH

Error message
Main
index

Sub-
index

Meaning of error
message

Measures Error

reaction

3 DeviceNet

communication

error

Send buffer overflow

PS off

1)

4 DeviceNet

communication

error

IO message could not be sent

PS off

1)

5 DeviceNet

communication

error

Bus off

PS off

1)

6 DeviceNet

communication

error

Overrun in the CAN controller

PS off

1)

0 DeviceNet

general

error

Common error: Communication has been
activated even though there is no
extension module plugged in. The
DeviceNet extension module is attempting
to read an unknown KO. Unknown
DeviceNet error.

PS off

1)

DeviceNet initialisation
error

DeviceNet extension module initialisation
error: Node number exists twice

65

1

DeviceNet communication
error

IO connection timeout

PS off

1)

2

General arithmetic error The FHPP factor group cannot be

calculated correctly.

PS off

70

3

Operating mode error

Prohibited change of operating mode, e.g.
torque control for CMMS ST in open-loop-
controlled operation or parametrisation
mode in FHPP, change in operating mode
when output stage is released.

PS off

1)

79 0 RS232

communication

error

Overrun when receiving RS232 commands. PS off

1)

1)

PS off
QStop
Warn
Ignore

Changeable with FCT

Switch off power section
Fast stop
Warning
Ignore

Table

8.2 Error messages