3. Product description

64

Festo.P.BE-CMMS-ST-G2-HW-EN

1008NH

Controller

release

START

Intermedicate curcuit

1

0

1

0

1

0

1

0

1

0

1

0

1

0

1

0

Holding brake

current-carrying

1

0

DOUT0: READY

DOUT1: MC

DOUT2: ACK

DOUT3: ERROR

Output stage

release

1

Output stage

switched on

0

Drive is moving

1

0

t1

t1

tx

t1

t

1

= 1.6 ms

tx

= x ms (ZK discharges)

Fig.

3.9 Behaviour during interruption of the intermediate circuit supply (error: end stage

off immediately)

Note

The holding brake of the EMMS-ST-?SB/-SEB is not suitable for
braking the motor.

3.5.13 Oscilloscope function

The implemented oscilloscope function is an important aid to help the commissioning
party optimise the controller settings without using a separate measuring device. The
function allows important signal sequences to be recorded over time. It consists of three
blocks:
• The initialisation section which runs at low priority and performs pre-calculations for

the actual measurement process.

• The measuring section runs at a high priority in the rule interrupt and records the

measuring channels. If the trigger condition occurs, the measurement process is
cancelled after a defined number of scan steps.