11 error messages, 12 behaviour when switching off enable, Error messages – Festo Контроллеры двигателя CMMS-ST User Manual

Page 62: Behaviour when switching off enable, 2 error messages, 7 behaviour when switching off controller enable

Advertising
background image

3. Product description

62

Festo.P.BE-CMMS-ST-G2-HW-EN

1008NH

3.5.11 Error messages

The following conditions are monitored for safe operation of the CMMS-ST:
- End stage temperature,
- Intermediate circuit voltage to minimum and maximum value,
- Initialisation errors,
- Check-sum error on parameter transfer,
- Communication error,
- Contouring error (with increment generator only)
- Homing run,
- Overload current / short circuit in the power end stage,
- Encoder system,
- Watchdog (processor monitoring).
All error messages are documented in chapter

8.2.2 Error messages.

3.5.12 Behaviour when switching off enable

Controller

enable

Drive is moving

1

0

1

0

1

0

1

0

Holding brake

Current-carrying

1

0

DOUT: READY

Output stage

release

1

0

tx

Motor controlled

ty

tx

= x ms (dependent on brake ramps)

ty

= x ms (dependent on set switch-off delay)

Fig.

3.7 Behaviour when switching off controller enable

Advertising