A. Technical data

128

Festo.P.BE-CMMS-ST-G2-HW-EN

1008NH

A.

Technical data

A.1

General information

Area Values

Storage
temperature:

-25°C to +70°C

Permitted temperature ranges

Operating
temperature:

0°C to +40°C

+40°C to +50°C with power
reduction 4% / K

Permitted installation height

Up to 1000 m above sea level
1000 to 3000 m above sea level with power
reduction

10% / 1000 m

Air humidity

Relative humidity up to 90%, non-condensing

Protection class

IP20

Contamination class

1

CE-conformity with low-voltage guideline:
EMC law: Current oscillations:

EN 50 178
EN 61 800 - 3
EN 61 000 - 3 - 2

Further certifications

UL / CSA

Specifications on EN ISO 13849-1

PL (performance level)

d

MTTFd (Mean Time To Failure dangerous)
Channel 1 (switching off PWM signals via X1)
Channel 2 (switching off driver supply via X3)


617.06 years
2853.88 years

PFH (Probability of Failure per Hour)

8.32 x 10

-8

Table

A.1 Technical data: Ambient conditions and qualifications

Features Values

Device dimensions (H*W*D)

160x50x160 mm

Weight 2.0

kg

Table

A.2 Technical data: Dimensions and weight

Features Values

Current regulator

20 μs

Speed regulator

200 μs

Position controller

400 μs

Table

A.3 Technical data: Cycle times