A. Technical data

Festo.P.BE-CMMS-ST-G2-HW-EN 1008NH

129

Area Values

Maximum motor cable length for interference emissions as per
EN 61800-3 (conforms to EN 55011, EN 55022)

Second environment

(Industrial)

l

≤ 25 m

Cable capacitance of one phase
against screen or between two
lines

C‘

≤ 200pF/m

Table

A.4 Technical data: Cable data

Sensors Values

Digital sensor

N/C contact:

R

cold

< 1 k

Ω

R

hot

> 10 k

Ω

Analogue sensor

Silicon temperature probe, e.g. KTY81 … 84

R

25

= 1 k

Ω

or

R

25

= 2 k

Ω

Table

A.5 Technical data: Motor temperature monitoring (in preparation)

A.2

Operation and display components

The CMMS-ST stepping motor controller has two LEDs on the front and one seven
segment display for showing the operating status.

Element Function

Seven segment display

Displays the operating mode and an error code
should an error occur

Ready LED (green)

Ready status

BUS LED (yellow)

CAN bus status display

Table

A.6 Display components