Mechanical installation, 1 important information, Important information – Festo Контроллеры двигателя CMMS-ST User Manual
Page 98
Advertising
![background image](/manuals/464486/98/background.png)
5. Mechanical installation
98
Festo.P.BE-CMMS-ST-G2-HW-EN
1008NH
5.
Mechanical installation
5.1
Important information
Note
• Use the CMMS-ST stepping motor controller as an integrated
device for control cabinet assembly only.
• The mounting position is vertical with the power supply lines
[X9] leading upwards
• Mount with the clip to the control cabinet plate
• Mounting clearance:
For sufficient ventilation, 100 mm of clearance to other
assemblies is required above and below the device.
• Pay attention to the fastening interval of 69 mm!
Advertising