Festo Контроллеры двигателя CMMS-ST User Manual

Page 61

Advertising
background image

3. Product description

Festo.P.BE-CMMS-ST-G2-HW-EN 1008NH

61

T

Transition condition

Actions of the user

T6

“Speed control” was selected in the commissioning
software.

Setpoint specification via AIN0/AGND

T8

“Positioning” was selected in the commissioning
software.

Set selection via
DIN0 … DIN3, DIN10, DIN11
Start for the positioning process:
DIN8=1

T9

All parameters for the jog mode were set in the
commissioning software (e.g. max. speed, acceleration
...).

Selection I/O mode:
DIN9=0, DIN12=1
Jog +: DIN10=1
Jog -: DIN11=1

T10

Selection

I/O

mode:

DIN9=0, DIN12=1

T11 Selection of the homing method and configuration of the

speeds and accelerations in the commissioning software.

Selection I/O mode: 0
DIN9=0, DIN12=0
Selection of positioning record 0
Start for positioning process: DIN8=1

T12 Drive

is

referenced.

T13

DIN5=0

T15

DIN5=0

T16

DIN5=0

T17

DIN4=0

T18

Write or read request to SD card such
as:
- Load parameters
- Save parameters
- Firmware download.

T19 The SD card was initialised successfully.

T20 “Load from SD after restart” was selected in the

commissioning software.

T21 Parameter record was loaded

T22 A fault has occurred which causes the end stage to be

switched off

T23

T24

Edge controlled fault acknowledgement
DIN5: 1 - 0

T25 The error was acknowledged and no other errors are

pending.

Table

3.20 I/O sequence control

Advertising