A. Technical data

130

Festo.P.BE-CMMS-ST-G2-HW-EN

1008NH

A.3

Interfaces

A.3.1 I/O interface [X1]

Digital inputs

Values

Signal level

18 … 30 V (high active)

Number 14

Reaction time to input

1.6 ms

Reaction time to sample input

< 100 μs

Protective function

Against polarity reversal

Table

A.7 Technical data: Digital inputs

Digital outputs

Values

Signal level

24 V (from logic supply)

Output current

<= 100 mA

Number

4

Output reaction time

< 2 ms

Protective function

Polarity reversal, short circuit, inductive load

Table

A.8 Technical data: Digital outputs

Analogue inputs

Values

Signal level

-10 … +10 V

Configuration Differential

input

Input reaction time

< 250 μs

Protective function

Overvoltage to ±30 V

Table

A.9 Technical data: Analogue inputs

Analogue outputs

Values

Signal level

0 … 10 V

Configuration Single-ended

against

AGND

Output reaction time

< 250 μs

Protective function

Short circuit against AGND

Table

A.10 Technical data: Analogue outputs