Festo Контроллеры двигателя CMMS-ST User Manual

Page 42

Advertising
background image

3. Product description

42

Festo.P.BE-CMMS-ST-G2-HW-EN

1008NH

Pin Name Mode 0

(DIN12=0)

Mode 1
(DIN12=1)

Mode 2
(DIN9=1 &
DIN12=0)

Mode 3
(DIN9=1 &
DIN12=1)

6

GND24 Reference potential for

digital I/Os

19 DIN0

Record selection 0
(high active)

Record selection 0 Record selection 0

7

DIN1

Record selection 1
(high active)

Record selection 1 Record selection 1

20 DIN2

Record selection 2
(high active)

Record selection 2 Record selection 2 CLK_24

8

DIN3

Record selection 3
(high active)

Record selection 3 Stop record

linking

DIR_24

21 DIN4

End stage enable (high active) Output stage

enable

Output stage
enable

Output stage
enable

9

DIN5

Controller enable (high active) Controller enable Controller enable Controller enable

22 DIN6

Limit switch 0

Limit switch 0

Limit switch 0

Limit switch 0

10 DIN7

Limit switch 1

Limit switch 1

Limit switch 1

Limit switch 1

23 DIN8

Start for positioning
procedure

Teach Start

record

linking

Start record
synchronisation

11 DIN9

High-speed input

“0” = jog mode

“1” = record
linking

“1” = slave
synchronisation

24 DOUT0 Ready for operation output

(high active)

12 DOUT1 Default motion complete

output (high active)

Speed

0

reached

25 DOUT2 Default start ack output

(low active)

Teach ack

Default start ack

Position
synchronised

13 DOUT3 Default error output Error

Error

Error

Table

3.14 Interface assignments

Signal: Description

AMON

AIN0 / #AIN0

Analogue output for monitor purposes
Differential analogue input with 12 bit resolution.
Alternatively, the differential analogue input can be parameterised with the function
Mode and Stop. (DIN12 and DIN13) (dependent on the parameterised control interface).

DOUT0...DOUT3 Digital outputs with 24 V level,

DOUT0 is permanently occupied with the function “Ready for operation”.
Additional outputs can be configured (Target reached, Axis in motion, Target speed
achieved.....)