power-supply shutdown automatic
Use the power-supply shutdown automatic command to enable the power supplies to automatically shut
down when the unit temperature exceeds the maximum operating temperature. Use the no form of this
command to disable.
Syntax Description
No subcommands.
Default Values
By default, this command is enabled.
Applicable Platforms
This command applies to the NetVanta 5000 Series units.
Command History
Release 7.1
Command was introduced.
Usage Examples
The following example enables the power supplies to shut down automatically if the temperature gets too
high:
(config)#power-supply shutdown automatic