Frame-relay lmi-t391dte <seconds – ADTRAN 5000 Series User Manual
Page 703

Command Reference Guide
Frame Relay Interface Config Command Set
61200990L1-35E
Copyright © 2005 ADTRAN
703
frame-relay lmi-t391dte <seconds>
Use the frame-relay lmi-t391dte command to set the T391 signal polling timer for the DTE endpoint.
Typical applications should leave the default value for this timer. Use the no form of this command to
return to the default value.
Syntax Description
<seconds>
Sets the timer value in seconds (valid range: 5 to 30).
Default Values
By default, the signal polling timer for the DTE endpoint is set to 10 seconds.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.
Command History
Release 1.1
Command was introduced.
Functional Notes
The T391 timer sets the time (in seconds) between polls to the Frame Relay network.
Usage Examples
The following example sets the T391 timer for 15 seconds:
(config)#interface frame-relay 1
(config-fr 1)#frame-relay lmi-t391dte 15