Loopback [dce | dte | line | remote | none – ADTRAN 5000 Series User Manual
Page 601
Advertising

Command Reference Guide
HSSI Interface Configuration Command Set
61200990L1-35E
Copyright © 2005 ADTRAN
601
loopback [dce | dte | line | remote | none]
Use the loopback command to initiate or remove a loopback.
Syntax Description
dce
Initiates a loopback on the DCE.
dte
Initiates a loopback on the DTE.
line
Initiates a local line loopback.
remote
Initiates a remote line loopback.
none
Removes an active loopback.
Default Values
By default, no loopbacks are active.
Applicable Platforms
This command applies to the NetVanta 5000 Series units.
Command History
Release 7.1
Command was introduced.
Usage Examples
The following example initiates a local line loopback on the HSSI interface:
(config)#interface hssi 1/1
(config-hssi 1/1)#loopback line
Advertising