Test-pattern [ones | zeros – ADTRAN 5000 Series User Manual
Page 509

Command Reference Guide
DSX-1 Interface Configuration Command Set
61200990L1-35E
Copyright © 2005 ADTRAN
509
test-pattern [ones | zeros]
Use the test-pattern command to activate the built-in pattern generator and begin sending the specified
test pattern. This pattern generation can be used to verify a data path when used in conjunction with an
active loopback. Use the no form of this command to cease pattern generation.
Syntax Description
ones
Generates a test pattern of continous ones.
zeros
Generates a test pattern of continous zeros.
Default Values
No defaults necessary for this command.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.
Command History
Release 1.1
Command was introduced.
Usage Examples
The following example activates the pattern generator for a stream of continuous ones:
(config)#interface t1 1/2
(config-t1 1/2)#test-pattern ones