databits [7 | 8]

Use the databits command to set the number of databits per character for a terminal session. This value
must match the configuration of your VT100 terminal or terminal emulator software. The default is 8
databits per character. Use the no form of this command to return to the default value.

Syntax Description

7

Specifies 7 data bits per character.

8

Specifies 8 data bits per character.

Default Values

By default, the databits are set to 8.

Applicable Platforms

This command applies to the NetVanta 300, 1000, 1000R, 2000, 3000, 4000, and 5000 and
Total Access 900 Series units.

Command History

Release 1.1

Command was introduced.

Usage Examples

The following example configures 7 databits per character for the console terminal session:

(config)#line console 0

(config-con 0)#databits 7