Flowcontrol [none | software in – ADTRAN 5000 Series User Manual
Page 474
Advertising

Command Reference Guide
Line (Console) Interface Config Command Set
61200990L1-35E
Copyright © 2005 ADTRAN
474
flowcontrol [none | software in]
Use the flowcontrol command to set flow control for the line console.
Syntax Description
none
Specifies no flow control.
software in
Configures AOS to derive flow control from the attached device.
Default Values
By default, flow control is set to none.
Applicable Platforms
This command applies to the NetVanta 300, 1000, 1000R, 2000, 3000, 4000, and 5000 and
Total Access 900 Series units.
Command History
Release 3.1
Command was introduced.
Usage Examples
The following example configures no flow control for the line console:
(config)#line console 0
(config-con 0)#flowcontrol none