ADTRAN 5000 Series User Manual

Page 507

Advertising
background image

Command Reference Guide

DSX-1 Interface Configuration Command Set

61200990L1-35E

Copyright © 2005 ADTRAN

507

signaling-mode [message-oriented | none | robbed-bit]

Use the signaling-mode command to configure the signaling type (robbed-bit for voice or clear channel
for data) for the DS0s mapped to the DSX-1 port.

Syntax Description

message-oriented

Specifies clear channel signaling on Channel 24 only. Use this signaling type with
QSIG installations.

none

Specifies clear channel signaling on all 24 DS0s. Use this signaling type with
data-only or PRI DSX-1 installations.

robbed-bit

Specifies robbed bit signaling on all DS0s. Use this signaling type for voice-only
DSX-1 applications.

Default Values

By default, the signaling mode is set to robbed-bit.

Applicable Platforms

This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.

Command History

Release 1.1

Command was introduced.

Usage Examples

The following example configures the DSX-1 port for PRI compatibility:

(config)#interface t1 1/2

(config-t1 1/2)#signaling-mode none

Advertising