P.007 terminal strip digital inputs configure – Rockwell Automation GV3000/SE AC Gen. Purpose & Vector Bookshelf Drive Start-Up and Reference Manual User Manual

Page 100

Advertising
background image

4-14

GV3000/SE AC Bookshelf Drive Software Reference, Version 6.06

4.6.2 Second Menu General Parameter Descriptions (P.007 to P.099)

An unasserted (open) or asserted (closed) input will select the input functions as
shown in table 4.2. If a function is not configured, the unasserted (open) state will be
applied.

P.007 Terminal Strip Digital Inputs Configure

The GV3000/SE
drive provides
multiple
configurations of
digital inputs 6, 7,
and 8 on the terminal
strip. This parameter
determines how
these inputs are
used.

The P.008 (Terminal
Strip Speed
Reference Source)
selection will limit the
selection of P.007
because the P.008
selection may use
one or more of digital
inputs 6 through 8.

Parameter Range:

Preset Configurations of Inputs 6, 7, and 8

Digital Input 6 Digital Input 7 Digital Input 8
(Terminal 19) (Terminal 18)

(Terminal 17)

0 = FWD/REV

RAMP 1/2

REM/LOC

1 =

Not used

FWD/REV

RAMP 1/2

2 =

Not used

FWD/REV REM/LOC

3 =

Not used

RAMP 1/2 REM/LOC

4 =

Not used

Not used

FWD/REV

5 =

Not used

Not used

RAMP 1/2

6 =

Not used

Not used

REM/LOC

7 =

Not used

Not used

Not used

8

*

= FWD/REV

TRQ/SPD REM/LOC

9* = Not used

TRQ/SPD REM/LOC

10* = Not used

TRQ/SPD

FWD/REV

11* = Not used

TRQ/SPD

RAMP 1/2

12* = Not used

Not used

TRQ/SPD

*

Vector regulation only.

Default Setting:

0

Parameter Type:

Configurable

Refer also to parameters:

P.008 Terminal Strip Speed Reference Source

!

ATTENTION: If a maintained start contact is used when the control
source = rE, switching from local to remote from the terminal strip will
cause power to be applied to the motor if the remote start contact is
closed. Stay clear of rotating machinery in this case. Failure to observe
this precaution could result in bodily injury.

Table 4.2 – Function Selection for Digital Inputs 6, 7, and 8

Input

Open (Unasserted)

Closed (Asserted)

FWD/REV

Forward

Reverse

RAMP 1/2

Ramp 1

Ramp 2

REM/LOC

Remote

Local

TRQ/SPD

Torque

Speed

Advertising