Rockwell Automation GV3000/SE AC Gen. Purpose & Vector Bookshelf Drive Start-Up and Reference Manual User Manual

Page 70

Advertising
background image

2-32

GV3000/SE AC Bookshelf Drive Software Reference, Version 6.06

Step 10.2 Verify that the AUTO LED is off (press the AUTO/MAN key until the AUTO

LED turns off).

This selects the local keypad as the speed
reference source.

Step 10.3 Press the

key or the

key once.

The monitor mode LEDs will all turn off and
the manual speed reference value will be
displayed. The speed reference value is in
the units defined in P.028. The display
shown here is only an example.

Step 10.4 If the speed reference is at minimum speed, then proceed to step 10.6.

If the speed reference is not at minimum speed, proceed to step 10.5.

Step 10.5 Press the

key to decrease the speed reference value.

Step 10.6 Press the ENTER key to return to monitor mode.

Step 10.7 Verify you have selected run mode and the forward direction. Press the

START key.

The drive is now running. The
keypad/display is in monitor mode, and the
RPM, RUN, and FWD LEDs are on.

The drive should be running at minimum
speed. The sample display shows
150 RPM.