2-12

GV3000/SE AC Bookshelf Drive Software Reference, Version 6.06

Step 5.14 Press the ENTER key to save the changed value.

After pressing ENTER, the same
parameter number is displayed. You can
now go to the next parameter.

Step 5.15 Press the

key to display P.004, Maximum Speed.

This parameter sets the maximum
speed in RPM.

Step 5.16 Press the ENTER key to display the default setting of P.004.

This displays the default setting for
Maximum Speed.

The default depends on the Power
Module type. The display shown here is
only an example.

S

530
9

$

+]

N:

754

3$66

581

-2*

$872

):'

5(9

352*

5(0

!

ATTENTION: The user is responsible for ensuring that driven machinery,
all drive-train mechanisms, and application material are capable of safe
operation at the maximum operating speed of the drive. For vector
regulation, overspeed detection in the drive determines when the drive
shuts down and is factory set to 130% of maximum speed. Failure to
observe this precaution could result in bodily injury.