Xl – Rockwell Automation GV3000/SE AC Gen. Purpose & Vector Bookshelf Drive Start-Up and Reference Manual User Manual

Page 55

Advertising
background image

Starting Up the Drive for Vector Regulation

2-17

Step 6.8 Press the ENTER key to display the default setting of U.001.

This displays the default setting for Encoder
PPR, 1024 PPR.

Step. 6.9 Press the

key to increase the PPR, or the

key to decrease the PPR

.

Select one of the four PPR values if an
encoder is used. Select SE if an encoder is
not used. See the description of U.001 in
chapter 4 for more information.

VALUE ENTERED:

Step 6.10 Press the ENTER key to save the changed value.

After pressing ENTER, the same parameter
is displayed. You can now move to the next
parameter.

!

ATTENTION: Do not use a 4096 PPR encoder with a 2-pole motor.
Overspeed and motor damage can result. Failure to observe this
precaution could result in bodily injury.