Starting Up the Drive for Volts/Hertz Regulation

1-7

Step 3.11 Press the ENTER key to display the default setting of P.003.

This shows that the default setting for
Minimum Speed is 5.0 Hz.

Step 3.12 Press the

key to increase minimum speed or the

key to decrease

minimum speed.

The adjustment range is:

0.5 Hz to the value set for P.004
(Maximum Speed).

VALUE ENTERED:

Step 3.13 Press the ENTER key to save the changed value.

After pressing ENTER, the same
parameter number is displayed. You can
now go to the next parameter.

Step 3.14 Press the

key to display P.004, Maximum Speed.

This parameter sets the maximum
speed in Hz.

In addition, the drive has overfrequency
protection by means of H.022. Refer to
the description of this parameter and be
sure to set it appropriate to your
application.