U.018 AC Line Volts

The phase-to-phase
line voltage provided
to the drive input
power terminals.

The value entered
should be within 10%
of actual line voltage.

Parameter Range:

300 to 565 VAC

Default Setting:

460

Parameter Type:

Configurable

Refer also to parameters:

N/A

U.019 Flux Current Regulator Proportional Gain

This parameter
determines the
performance of the
magnetizing current
regulator.

For most
applications, it is
recommended that
this parameter not be
changed.

Parameter Range:

0.10 to 31.99

Default Setting:

Power Module-dependent, see Appendix C

Parameter Type:

Tunable

Refer also to parameters:

U.020 Flux Current Regulator Integral Gain

U.020 Flux Current Regulator Integral Gain

This parameter
determines the
performance of the
magnetizing current
regulator.

For most
applications, it is
recommended that
this parameter not be
changed.

Parameter Range:

10.0 to 628.0 radians/second

Default Setting:

50.0

Parameter Type:

Tunable

Refer also to parameters:

U.019 Flux Current Regulator Proportional Gain