H.000 motor nameplate volts, H.001 motor nameplate base frequency – Rockwell Automation GV3000/SE AC Gen. Purpose & Vector Bookshelf Drive Start-Up and Reference Manual User Manual

Page 141

Advertising
background image

Programming Reference

4-55

4.6.3 Second Menu V/Hz Parameter Descriptions (H.000 to H.022)

Base frequency is the frequency at which the output voltage reaches Motor
Nameplate Voltage (H.000). Below base frequency, the output voltage varies with
output frequency according to the V/Hz adjustment in parameter H.018 (Volts/Hertz
Curve Type). Above base frequency, output voltage is held constant as frequency
increases (constant horsepower range).

The V/Hz ratio is affected by the selection of Volts/Hertz Curve Type in H.018 and the
setting of Torque Boost Voltage in H.003. See figure 4.10.

H.000 Motor Nameplate Volts

This parameter
identifies the motor
nominal voltage as it
appears on the motor
nameplate.

Parameter Range:

100 VAC to 690 VAC

Default Setting:

460 VAC

Parameter Type:

Configurable

Refer also to parameters:

N/A

H.001 Motor Nameplate Base Frequency

This parameter
configures the V/Hz
ratio.

Parameter Range:

30.0 to 200.0 Hz

Default Setting:

60.0 Hz

Parameter Type:

Configurable

Refer also to parameters:

H.003 Torque Boost Voltage
H.018 Volts/Hertz Curve Type

Figure 4.10 – Volts/Hz Ratio





Maximum

V/Hz

+

Minimum

V/Hz

Motor

Voltage,

H.000
(volts)

Output Frequency

(Hz)

Advertising