Sl – Rockwell Automation GV3000/SE AC Gen. Purpose & Vector Bookshelf Drive Start-Up and Reference Manual User Manual

Page 47

Advertising
background image

Starting Up the Drive for Vector Regulation

2-9

Step 5.4 Press the ENTER key to display the default setting of P.001.

This displays the default setting for
acceleration time (20.0 seconds).

Step 5.5 Press the

key to increase acceleration time, or the

key to decrease

acceleration time.

The adjustment range is:

0.1 to 999.9 seconds.

VALUE ENTERED:

Step 5.6 Press the ENTER key to save the changed value.

After pressing ENTER, the same
parameter number is displayed. You can
now go to the next parameter.

Step 5.7 Press the

key to display P.002, Decel Time 1 (RAMP 1).

This parameter sets the deceleration
time in seconds. The default stop
method is coast-to-stop, set in P.025.



530
9

$

+]

N:

754

3$66

581

-2*

$872

):'

5(9

352*

5(0

SL

530
9

$

+]

N:

754

3$66

581

-2*

$872

):'

5(9

352*

5(0

S

530
9

$

+]

N:

754

3$66

581

-2*

$872

):'

5(9

352*

5(0

Advertising