The Keypad

The drive’s keypad has nine membrane keys that are used to monitor, program, and
control the drive.

If the control source is changed, the AUTO/MAN selection may be
changed as well. When the control source is changed to OP or rE,
the AUTO/MAN selection is forced to AUTO. If the control source is
changed to LOCL or SErL, the AUTO/MAN selection is forced to
MANUAL. However, if the control source is changed from LOCL or
SErL or vice versa, the AUTO/MAN selection is not changed.

Note that this key is not active if the control source is SErL. Refer to
the P.000 parameter description for more information on control
source selection.

Refer to the following parameters for more information on the

AUTO/MAN key:

P.052 AUTO/MAN Key Disable

P.053 Manual Reference Preset Enable

Use the AUTO/MAN key to switch between the auto speed reference
and the manual speed reference as shown below.

AUTO/MAN

Status

Control Source (P.000)

Speed Reference

Source

AUTO selected Local keypad/display

(P.000=LOCL)

Terminal strip

Terminal strip remote
inputs (P.000=rE)

Terminal strip

Option port (P.000=OP)

Network

Serial port (P.000=SErL)

Terminal strip

MAN selected

Local keypad/display
(P.000=LOCL)

Local keypad/display
or OIM/CS3000

Terminal strip remote
inputs (P.000=rE)

Local keypad/display
or OIM/CS3000

Option port (P.000=OP)

Local keypad/display
or OIM/CS3000

Serial port (P.000=SErL)

Local keypad/display
or OIM/CS3000

!

ATTENTION: When switching from auto to manual, or
manual to auto, the drive will ramp to the reference level
provided by the new source at the rate specified in P.001
(Accel Time 1), P.002 (Decel Time 1), P.017 (Accel Time
2), or P.018 (Decel Time 2). Be aware that an abrupt
speed change may occur depending upon the new
reference level and the rate specified in these
parameters. Failure to observe this precaution could
result in bodily injury.

&%