Rockwell Automation GV3000/SE AC Gen. Purpose & Vector Bookshelf Drive Start-Up and Reference Manual User Manual

Page 72

Advertising
background image

2-34

GV3000/SE AC Bookshelf Drive Software Reference, Version 6.06

Step 11. Run the Drive

This step describes how to increase the speed reference across the speed range and
check for proper motor operation. This step assumes that P.000 is set to LOCL
(control is local) and the motor is connected to the load.

Step 11.1 Press the START key.

The drive is now running and the
keypad/display is in monitor mode.

Step 11.2 Press the

or

key once. All monitor mode LEDs will turn off.

Increase the speed reference to the maximum value by using the

key.

Wait five seconds or press the ENTER key to return to monitor mode.

This increases the drive speed reference
and the motor will rotate up to maximum
speed.

The monitor mode LEDs turn off when the
reference is changed.

The display now shows the actual drive
speed. Your speed display may be different.