Step 6. Program the Second Menu Vector (U) Parameters

This step describes how to program the Vector (U) parameters that apply to vector
regulation only. You will not be adjusting any parameters for V/Hz regulation (H
parameters) in this procedure.

Step 5.21 Press the

key to decrease current limit percent.

Note that changing current limit rating affects the maximum

attainable torque the motor can produce.

The adjustment range for current limit is:

U.006 (Magnetizing Current) to 150%.

VALUE ENTERED:

Step 5.22 Press the ENTER key to save the entered value.

After pressing ENTER, the same parameter
number is displayed. You can now move to
the next parameter.

Step 6.1 Press the PROG key to return to the main menu level.

The display will return to the First Menu
General (P) parameters.