Ppendix, Power module-dependent parameter default values – Rockwell Automation GV3000/SE AC Gen. Purpose & Vector Bookshelf Drive Start-Up and Reference Manual User Manual

Page 197

Advertising
background image

Power Module-Dependent Parameter Default Values

C-1

A

PPENDIX

C

Power Module-Dependent

Parameter Default Values

Second Menu General Parameters (USA Defaults)

Second Menu Volts/Hertz Parameters (USA Defaults)

Second Menu Vector Parameters (USA Defaults)

Parameter

No.

Parameter

Name

Power Module

31ER4060

31ET4060

38ER4060

38ET4060

55ER4060

55ET4060

85ER4060

85ET4060

126ER4060

126ET4060

P.047

Carrier Freq. (kHz)

2

2

2

2

2

Parameter

No.

Parameter

Name

Power Module

31ER4060

31ET4060

38ER4060

38ET4060

55ER4060

55ET4060

85ER4060

85ET4060

126ER4060

126ET4060

H.002

Motor Namepl. Amps

1.3

2.7

3.8

6.1

9.0

Parameter

No.

Parameter

Name

Power Module

31ER4060

31ET4060

38ER4060

38ET4060

55ER4060

55ET4060

85ER4060

85ET4060

126ER4060

126ET4060

U.004

Motor Namepl. Amps

1.6

3.0

3.0

4.4

7.1

U.005

Motor Namepl. RPM

1736

1744

1744

1726

1722

U.006

Magnetizing Current

51.2

59.4

59.4

56.7

54.5

U.012

Speed Reg. Prop. Gain

5.00

5.00

5.00

5.00

5.00

U.013

Speed Reg. Int. Gain

5.00

5.00

5.00

5.00

5.00

U.014

Torque Reg. Prop.
Gain

0.40

0.40

0.40

0.40

0.40

U.015

Torque Reg. Integral
Gain

200.0

200.0

200.0

200.0

200.0

U.016

Field Weaken Start
RPM

1736

1744

1744

1726

1722

U.017

Motor Top Speed

1736

1744

1744

1726

1722

U.019

Flux Current Reg.
Prop. Gain

0.30

0.30

0.30

0.30

0.30

U.021

Rotor Time Constant

250

250

250

250

250

U.022

Motor Namepl. HP

1.0

2.0

3.0

5.0

7.0

U.032

SVC Flux Curr. Reg.
Gain

1000

1000

1000

1000

1000

Advertising