Identity object, C.1 identity object – Rockwell Automation RECOMM-CNET ControlNet Communications Module User Manual

Page 118

Advertising
background image

C-2

ControlNet Communications Module

C.1 Identity Object

Class Code

Instances

The number of instances depends on the number of components in
the device connected to the module. This number of components
can be read in Instance 0, Attribute 2.

Class Attributes

Instance Attributes

Hexadecimal

Decimal

0x01

1

Instance

Description

0

Class

1

Entire device

2 - 7

DPI Peripherals on ports 1 - 6

Attribute

ID

Access

Rule

Name

Data Type

Description

2

Get

Max Instance

UINT

Total number of
instances

Attribute

ID

Access

Rule

Name

Data Type

Description

1

Get

Vendor ID

UINT

5 = Reliance Electric

2

Get

Device Type

UINT

120

3

Get

Product Code

UINT

Number identifying
product name and
rating

4

Get

Revision:
Major
Minor

STRUCT of
USINT
USINT

Value varies
Value varies

5

Get

Status

WORD

Bit 0 = Owned
Bit 2 = Configured
Bit 10 = Recoverable
fault
Bit 11 =
Unrecoverable fault

6

Get

Serial Number

UDINT

Unique 32-bit number

Advertising