Selecting master- slave, 5 selecting master-slave – Rockwell Automation RECOMM-CNET ControlNet Communications Module User Manual

Page 24

Advertising
background image

4-4

ControlNet Communications Module

4.5

Selecting Master-Slave

A hierarchy determines the type of device with which the module
exchanges data. In a Master-Slave hierarchy, a module exchanges
data with a scanner.

To set a Master-Slave hierarchy

Step 1.

Enable the desired I/O in DPI I/O Config (13). Refer to
figure 4.3.

Step 2.

Set the bits in the M-S Input (25). This parameter
determines the data transmitted from the scanner to the
drive. A “1” enables the I/O. A “0” disables the I/O.

Bit 0 is the right-most bit. In figure 4.4, it is highlighted and equals
“1.”

Step 3.

Set the bits in the M-S Output (26). This parameter
determines the data transmitted from the drive to the
scanner. A “1” enables the I/O. A “0” disables the I/O.

Bit 0 is the right-most bit. In figure 4.5, it is highlighted and equals
“1.”

Step 4.

Reset the module. Refer section 4.7.3 for this procedure.

Figure 4.4 – Master-Slave Input Screen on an LCD OIM

Figure 4.5 – Master-Slave Input Screen on an LCD OIM

Bit

Description

0

Logic Command/Reference (Default)

1

Datalink A Input

2

Datalink B Input

3

Datalink C Input

4

Datalink D Input

5 - 15 Not Used

Port 5 Device

RECOMM-CNET

Parameter #: 25
M-S Input
x x x x x x x x x x x 0 0 0 0

1

Cmd/Ref

b00

Bit

Description

0

Status/Feedback (Default)

1

Datalink A Output

2

Datalink B Output

3

Datalink C Output

4

Datalink D Output

5 - 15 Not Used

Port 5 Device

RECOMM-CNET

Parameter #: 26
M-S Output
x x x x x x x x x x x 0 0 0 0

1

Status/Fdbk

b00