Configuring the ControlNet Module

4-9

14

DPI I/O Active
I/O that the module is actively transmitting. The
value of this parameter will usually be equal to the
value of parameter 13 - DPI I/O Config.

Default:

xxx0 0001

Bit Values:

0 = I/O disabled
1 = I/O enabled

Type:

Read Only

Bit Definitions
0 = Cmd/Ref
1 = Datalink A
2 = Datalink B
3 = Datalink C
4 = Datalink D
5 = Not Used
6 = Not Used
7 = Not Used

25

M-S Input
Configures the I/O Data to be transferred from the
network to the drive.

Default:

xxx0 0001

Bit Values:

0 = I/O disabled
1 = I/O enabled

Type:

Read/Write

Reset Required: Yes

Bit Definitions
0 = Cmd/Ref
1 = Datalink A
2 = Datalink B
3 = Datalink C
4 = Datalink D
5 = Not Used
6 = Not Used
7 = Not Used

26

M-S Output
Configures the I/O Data to be transferred from the
drive to the network.

Default:

xxx0 0001

Bit Values:

0 = I/O disabled
1 = I/O enabled

Type:

Read/Write

Reset Required: Yes
Bit Definitions
0 = Cmd/Ref
1 = Datalink A
2 = Datalink B
3 = Datalink C
4 = Datalink D
5 = Not Used
6 = Not Used
7 = Not Used

27

Ref Adjust
Percent scale factor for the Reference from the
Network.

Default: 100.00
Minimum: 0.00
Maximum: 200.00
Type: Read/Write
Reset Required: No

Table 4.4 – Module Configuration Status Parameters

No.

Name and Description

Details

Bit

Default

1

0

0

0

0

x x

x

0

1

2

3

4

5

7

6

Bit

Default

1

0

0

0

0

x x

x

0

1

2

3

4

5

7

6

Bit

Default

1

0

0

0

0

x x

x

0

1

2

3

4

5

7

6