D-2

ControlNet Communications Module

Logic Status Word

x

x

x

Reference
Select

000 = No Command
001 = Ref. 1 (Ref A Select)
010 = Reserved
011 = Ref. 3 (Preset 3)
100 = Ref. 4 (Preset 4)
101 = Ref. 5 (Preset 5)
110 = Ref. 6 (Preset 6)
111 = Ref. 7 (Preset 7)

x

MOP
Decrement

0 = Not Decrement
1 = Decrement

1

A 0 = Not Stop condition (logic 0) must first be present before a 1 = Start condition
will start the drive.

Logic Bits

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Command

Description

Logic Bits

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

Status

Description

x Ready

0 = Not Ready
1 = Ready

x

Active

0 = Not Active
1 = Active

x

Command
Direction

0 = Reverse
1 = Forward

x

Actual
Direction

0 = Reverse
1 = Forward

x

Accel

0 = Not Accelerating
1 = Accelerating

x

Decel

0 = Not Decelerating
1 = Decelerating

x

Alarm

0 = No Alarm
1 = Alarm

x

Fault

0 = No Fault
1 = Fault

x

At Speed

0 = Not At Reference
1 = At Reference

x

x

x

Local
Control

000 = Port 0 (TB)
001 = Port 1
010 = Port 2
011 = Port 3
100 = Port 4
101 = Port 5
110 = Port 6
111 = No Local