2-111

Cisco Catalyst Blade Switch 3130 and 3032 for Dell Command Reference

OL-13271-03

Chapter 2 Cisco Catalyst Blade Switch 3130 and 3032 for Dell Cisco IOS Commands

diagnostic monitor

diagnostic monitor

Use the diagnostic monitor global configuration command to configure health-monitoring diagnostic
testing. Use the no form of this command to disable testing and to return to the default settings.

diagnostic monitor interval switch number test {name | test-id | test-id-range | all} hh:mm:ss

milliseconds day

diagnostic monitor switch number test {name | test-id | test-id-range | all}

diagnostic monitor syslog

diagnostic monitor threshold switch number test {name | test-id | test-id-range | all} failure count

count

no diagnostic monitor interval switch number test {name | test-id | test-id-range | all}

no diagnostic monitor switch number test {name | test-id | test-id-range | all}

no diagnostic monitor syslog

no diagnostic monitor threshold switch number test {name | test-id | test-id-range | all} failure

count count

Syntax Description

interval

Configure the interval between tests.

switch number

Specify the switch number, which is the stack member number. If the
switch is a standalone switch, the switch number is 1. If the switch is in a
stack, the range is 1 to 9, depending on the switch member numbers in the
stack.

This keyword is supported only on stacking-capable switches.

test

Specify the tests to be run.

name

Specify the name of the test. For more information, see the “Usage
Guidelines” section.

test-id

Specify the ID number of the test. The range is from 1 to 7. For more
information, see the “Usage Guidelines” section.

test-id-range

Specify more than one test with the range of test ID numbers. For more
information, see the “Usage Guidelines” section.

all

Specify all of the diagnostic tests.

hh:mm:ss

Configure the monitoring interval in hours, minutes, and seconds. For
formatting information, see the “Usage Guidelines” section.

milliseconds

Configure the monitoring interval in milliseconds (ms). The range is from
0 to 999 ms.

day

Configure the monitoring interval in the number of days. The range is from
0 to 20 days. For formatting information, see the “Usage Guidelines”
section.

syslog

Enable the generation of a syslog message when a health-monitoring test
fails.