System env temperature threshold yellow – Dell POWEREDGE M1000E User Manual

Page 836

Advertising
background image

2-806

Cisco Catalyst Blade Switch 3120 for HP Command Reference

OL-12248-03

Chapter 2 Cisco Catalyst Blade Switch 3120 for HP Cisco IOS Commands

system env temperature threshold yellow

system env temperature threshold yellow

Use the system env temperature threshold yellow global configuration command on the switch stack
or on a standalone switch to configure the difference between the yellow and red temperature thresholds
that determines the value of yellow threshold. Use the no form of this command to return to the default
value.

system env temperature threshold yellow value

no system env temperature threshold yellow value

Syntax Description

Defaults

These are the default values:

Yellow—80°C

Red—85°C

Command Modes

Global configuration

Command History

Usage Guidelines

You cannot configure the green and red thresholds but can configure the yellow threshold. Use the
system env temperature threshold yellow value global configuration command to specify the
difference between the yellow and red thresholds and to configure the yellow threshold. For example, if
the red threshold is 66 degrees C and you want to configure the yellow threshold as 51 degrees C, set
the difference between the thresholds as 15 by using the system env temperature threshold yellow 15
command.

Note

The internal temperature sensor in the switch measures the internal system temperature and might vary
±5 degrees C.

value

Specify the difference between the yellow and red threshold values (in Celsius). The
range is 10 to 25. The default value is 10.

Release

Modification

12.2(40)EX1

This command was introduced.