energywise query

energywise query

Use the energywise query privileged EXEC command to display power information or to power the
entities or PoE ports in the domain.

energywise query importance importance {keywords word,word,... | name name} collect {delta

| usage}

energywise query importance importance {keywords word,word,... | name name} set level level

energywise query importance importance {keywords word,word,... | name name} sum {delta |

usage}

Syntax Description

importance importance Filter the results based on the importance value. Only entities with values

less than or equal to the specified value appear.

The importance range is from 1 to 100.

keywords word,word,... Filter the results based on one or more of the specified keywords.

When specifying multiple keywords, separate the keywords with commas,
and do not use spaces between keywords.

You can enter alphanumeric characters and symbols such as #, (, %, !, or
&.

Do not use an asterisk (*) or a blank space between the characters and
symbols.

name name

Filter the results based on the name.

For the wildcard, use * or name* with the asterisk at the end of the name
phrase.

You can enter alphanumeric characters and symbols such as #, (, %, !, or
&.

Do not use an asterisk (*) or a blank space between the characters and
symbols.

collect {delta | usage}

Display the delta or usage values for the entities or the PoE ports.

delta—Display only the differences between the current and available
power usage.

usage—Display only the current power usage.

set level level

Set the power level of the entities or the PoE ports.

The range is from 0 to 10.

An entity supports level 1 to level 10.

A PoE port supports level 0 to level 10.

sum {delta | usage}

Display the sum of the delta or usage values for the entities or the PoE ports.

delta—Display only the sum of the differences between the current and
available power usage.

usage—Display only the current power usage.