4 brooktrout driver, 5 serial modem driver, 6 27951–28027: ipfax driver – FaxBack NET SatisFAXtion 8.7 (Including R3) - Manual User Manual

Page 174

Advertising
background image

4 – Appendices

NET SatisFAXtion 8.7 Manual

174

1621 No dial tone:

By default, the modem will listen for dial tone before try-

ing to place an outbound call. The most common cause of this error is not hav-
ing a working phone line plugged into this port. If the phone lines do not
provide dial tone, the modem must be configured to not detect dial tone before
dialing (see

dial_progress_mode

). Error type:

NO_DIAL_TONE

.

1622 Modem did not detect fax device on answering side:

Call was not an-

swered by a fax. Error type:

NO_ANSWER

.

1623 Modem did not detect fax device on answering side:

The driver re-

ceived something other than +FCON from the modem upon answering the line.
Error type:

NON_RETRYABLE

.

1624 No answer:

No response from modem during answer for receive. Error

type:

NON_RETRYABLE

.

1625 Call hung up before fax was complete:

The modem returned a NO

CARRIER while sending. Error type:

RETRYABLE

.

1624 No Answer, remote device did not respond to handshake:

The call

connected but the remote device failed to respond to repeated attempts to
handshake. The timer is 35 seconds. Error type:

NON_RETRYABLE

.

1626 Modem aborted the fax:

The modem returned an +FHNG:0 even

though the fax was not complete. Error type:

RETRYABLE

.

4.1.4

Brooktrout Driver

4.1.5

Serial Modem Driver

10785 Windows serial device name unknown:

Cannot access the config-

ured modem. Check that no other application is using the modem.
10786 The serial device is in use by another program:

Cannot access the

configured modem. Check that no other application is using the modem.

4.1.6

27951–28027: IPFax Driver

27951 Bad open ring 0 / kernel mode driver:

There is another instance of

the IPFax driver already loaded, or the Windows account attempting to load
the driver does not have Administrative permissions.
27969 Send collided with receive:

An outbound port was allocated just as

the port began to receive a call. Error type:

BUSY

.

27975 WsaSendTo error:

The gateway address is not a valid IP address. Er-

ror type:

NON_RETRYABLE

.

27976 SIP Invite sent 7 times with no response: The gateway did not re-
spond to SIP Invite requests. Check the configured gateway IP address, and
any firewall in between. Error type:

RETRYABLE

.

Advertising