FaxBack NET SatisFAXtion 8.7 (Including R3) - Manual User Manual

Page 175

Advertising
background image

4 – Appendices

NET SatisFAXtion 8.7 Manual

175

27977 Timeout waiting for invite final response:

Call was not answered in

the configured time period. Error type:

NO_ANSWER

.

27978 Unknown

SIP response code: Received nonstandard SIP code from

media gateway. See extended error code. Error type:

RETRYABLE

.

27979 Timeout waiting for reinvite to fax:

The call connected, but the

gateway failed to send a reinvite for T.38 either because there were no fax
tones detected on the remote side or because the gateway does not support
T.38. Error type:

RETRYABLE

.

27980 Timeout waiting for ACK of OK for reinvite to fax:

Media gateway

incompatibility or severe network issues. Error type:

RETRYABLE

.

27981 SIP response sent 7 times with no ACK: Media gateway incompati-
bility or severe network issues. Error type:

RETRYABLE

.

27982 Reinvite OK received without

T.38 media: Media gateway incompati-

bility. Error type:

RETRYABLE

.

27983 SIP bye received before fax was completed: The remote fax device
hung up before the fax was completed. The gateway also did not include a
Q.850 cause code for this disconnect, otherwise this would likely be 0x7210
Normal Call Clearing instead. Error type:

RETRYABLE

.

27984 Unable to open even

RTP port followed by consecutive RTCP

port. Error type:

NON_RETRYABLE

.

27985 No Answer, remote device did not respond to handshake:

The call

connected and T.38 communication was established, but the remote device
failed to respond to repeated attempts to handshake. This commonly occurs
when using T38_INVITE to initiate T.38 media without the initial RTP audio
phase. The timer is 35 seconds. Error type:

RETRYABLE

.

27986 Remote fax cannot receive:

The remote fax device is configured to

not receive faxes. Error type:

NON_RETRYABLE

.

27987 Can’t agree on bit rate:

The modem and the remote unit couldn’t fall

back to or agree upon any bit rate. This is most often caused by poor line condi-
tion. Error type:

NON_RETRYABLE

.

27988 Wrong response after training:

After sending 1.5 seconds of train-

ing data, the remote unit should have sent a CFR or FTT frame. It sent some-
thing else. Error type:

RETRYABLE

.

27989 No FTT or CFR received after 3 DCS/training sequences:

The call

connected and T.38 communication was established. The receiving and sending
devices exchanged CSI/DIS and TSI/DCS/training signals. After that, the re-
ceive side is expected to send a CFR (confirmation) or FTT (failure to train), it
did neither. Handshaking was attempted and failed twice more, at which point
IPFax terminated the call. Error type:

RETRYABLE

.

27990 No response after sending 3 end of page commands:

After reach-

ing the end of the page, IPFax sends an end-of-page command (MPS) and ex-
pects to receive an acknowledgment (MCF) from the remote device. IPFax did

Advertising