Port1/port2 setting menu, Port1/port2 setting menu -8 – KEYENCE DV-90 User Manual

Page 132

Advertising
background image

6-8

E DV-90-IM

6

Setti

ng

6-2 Setting Items of the DV-90

BCD output

In this output, 12 bits are delimited into 4 bits each, and each chunk is assigned with a hundreds
digit, tens digit, and units digit, respectively, in the decimal number. Values between 0 and 999
can be output.

Output number: 235 (The hundreds digit is expressed as “0010” in binary notation.)

(The tens digit is expressed as “0011” in binary notation.)
(The units digit is expressed as “0101” in binary notation.)

PORT1/PORT2 Setting Menu

„ Menu list

PORT1/PORT2 setting menu

Communication settings

Manual
Auto

1

Default

Input limit

1

Input digit limit start digit

1,

2

Input digit limit valid digits

1,

2

Receive format

1

Trigger mode

1

Read quality check function

1

Read quality threshold

1, 3

Read error check

1

RTS/CTS protocol

4, 5

DM head address

4, 6

PLC trigger notice area

4, 6

PLC unit ID

4, 6, 7

1 Setting is possible only when “PORT1/PORT2 Unit” is set to “Code Reader”.
2 Setting is possible only when “Input Limit” is set to “OFF”.
3 Setting is possible only when “Quality Check” is set to “ON”.
4 Setting is possible only in the “PORT2 setting menu”.
5 Setting is possible only when “PORT2 Unit” is set to “PC”.
6 Setting is possible only when “PORT2 Unit” is set to “PLC Link”.
7 Setting is possible only when “PLC Type” is set to “MELSEC/SYSMAC”.

Output number

2

3

5

OUT

12

11

10

9

8

7

6

5

4

3

2

1

ON/OFF

OFF OFF ON OFF OFF OFF ON

ON OFF ON OFF ON

Example