KEYENCE DV-90 User Manual

Page 215

Advertising
background image

9-15

9

E DV-90-IM

PLC Link

9-2 Device Assignment

„ DMs in which data is written

• The DMs are assigned with the addresses specified in “X+01 to +03” at the head (Y1 to Y3).
• Making a selection from Data 1 through 3 depends on the “Verify Type” to be used as shown in

the following list. Refer to page 9-17 for details.

* The data may be used when “Output Data” is “Verify Limit”.

* “Data 1” is the data of the “first reading”, “Data 2” is the data of the “second reading”, and “Data 3” is the

data of the “third reading”.

• The maximum number of data digits that can be written is 100.

Even when the code reader has read more than 100 digits, only up to the 100th digit can be written.
If the number of digits in the data is less than 100, it is possible to use the DMs in which no data
is to be written.

• ASCII codes or double-byte codes are written in “Y*+01 to +50”. Note that a double-byte code

occupies two digits.

• The data is written in a DM of “Y*+01 to +50” from the upper byte to the lower byte. When odd-

byte data is written, 00h is written in the last digits (the lower byte of the last data). The previous
data is retained after the last digit.

DM

Description

Data description

Writing from

the DV-90

Writing from

the PLC

Y1+00

Data 1 Number of Digits Check

Area

1 to 100: Number of digits of

Data 1

Yes No

Y1+01

Data 1 Check Area

Data of the first to second digit

Yes

No

Y1+02

Data of the third to fourth digit

Y1+03

Data of the fourth to fifth digit

...

Y1+50

Data of the 99th to 100th digit

Y2+00

Data 2 Number of Digits Check

Area

1 to 100: Number of digits of

Data 2

Yes

No

Y2+01

Data 2 Check Area

Data of the first to second digit

Yes

No

Y2+02

Data of the third to fourth digit

Y2+03

Data of the fourth to fifth digit

...

Y2+50

Data of the 99th to 100th digit

Y3+00

Data 3 Number of Digits Check

Area

1 to 100: Number of digits of

Data 3

Yes

No

Y3+01

Data 3 Check Area

Data of the first to second digit

Yes

No

Y3+02

Data of the third to fourth digit

Y3+03

Data of the fourth to fifth digit

...

Y3+50

Data of the 99th to 100th digit

Verify Type

Data 1

Data 2

Data 3

Verify Normal

Yes

Yes/No(*)

Yes/No(*)

Verify Active

Yes

Yes/No(*)

Yes/No(*)

Verify Step,

Verify 2 points

Yes

Yes

No

Verify 3points-A

Yes

Yes

Yes

Verify 3points-B

Yes

Yes

Yes

Advertising