5 settings, Settings of the dv-90, Settings -26 settings of the dv-90 -26 – KEYENCE DV-90 User Manual
Page 226: Settings -26, Settings
9-26
E DV-90-IM
9
PLC Link
9-5
Settings
Settings of the DV-90
Set the DV-90 as follows.
1
Set “PORT2 Unit” in “Main” to “PLC Link”.
2
Select the “PLC Type” in “Main” from among “KEYENCE KV”, “MELSEC”, and
“SYSMAC” according to the PLC to be used.
3
Configure “Baud” and “Format (data length, parity, stop bit length)” in “PORT2”
according to the PLC.
The default values are set as follows depending on the “PLC Type” setting.
4
Set the “DM Address” in “PORT2”.
For the DM assignment, refer to page 9-4.
5
Set the “PLC Time Area” in “PORT2”.
Set the “PLC Time Area” to “ON” when using “X+06 Read Trigger Notice Area” on the PLC
link, and controlling the reading of the code reader connected via the PLC link. (
Refer to
9-8)
6
Set the “PLC Unit ID” in “PORT2”.
PLC type
KV Series
MELSEC Series
SYSMAC Series
Baud rate
9600 bits/s
9600 bits/s
9600 bits/s
Data length
8 bits
8 bits
7 bits
Parity
Even
Odd
Even
Stop bit length
1 bit
1 bit
2 bits