9-5

Settings

Settings of the DV-90

Set the DV-90 as follows.

1

Set “PORT2 Unit” in “Main” to “PLC Link”.

2

Select the “PLC Type” in “Main” from among “KEYENCE KV”, “MELSEC”, and

“SYSMAC” according to the PLC to be used.

3

Configure “Baud” and “Format (data length, parity, stop bit length)” in “PORT2”

according to the PLC.
The default values are set as follows depending on the “PLC Type” setting.

4

Set the “DM Address” in “PORT2”.

For the DM assignment, refer to page 9-4.

5

Set the “PLC Time Area” in “PORT2”.

Set the “PLC Time Area” to “ON” when using “X+06 Read Trigger Notice Area” on the PLC
link, and controlling the reading of the code reader connected via the PLC link. (

Refer to

9-8)

6

Set the “PLC Unit ID” in “PORT2”.

PLC type

KV Series

MELSEC Series

SYSMAC Series

Baud rate

9600 bits/s

9600 bits/s

9600 bits/s

Data length

8 bits

8 bits

7 bits

Parity

Even

Odd

Even

Stop bit length

1 bit

1 bit

2 bits