How to Use the Setup

So
ftw
a

re

2

Select “Date Compare”.

3

Configure the settings.

4

When the [OK] button is clicked, “Date Compare” is activated.

01 14111122223333 17 XXXXXX

Product code Manufactured date

In the case of the barcode shown above, when judging the products manufactured within 30 days
from the time the barcodes are read as Verify OK, the Date Compare range is as follows. Register
the product code in Master data 1 beforehand.

Note

• When the Date Compare is activated, the selected master data is overwritten.
• Setting range is –10000 to +10000.
• The number in the setting range is expressed in five digits. When “10” is entered, “00010”

is registered.

Verify Limit
Direction

Master data to be used to
set the upper and lower limits

Maximum range

Digit Start

Minimum range

Logic

Example

7-3 Setting Procedure