KEYENCE DV-90 User Manual
Page 229
9-29
9
E DV-90-IM
PLC Link
AJ71QC24 (-R2), A1SJ71QC24 (-R2)
QJ71C24 (-R2), QJ71C24N (-R2/R4)
Set the communication conditions on the GX Developer.
(“PLC parameter” > “I/O assignment”)
(“PLC parameter” > “I/O assignment” > “Switch”)
Prefix setting
0 0
Mode configuration
4 (dedicated protocol mode, ASCII mode, type 4)
Operation setting
Independent operation
Data bit length
8 bits
Parity
Odd
Stop bit length
1 bit
Sum check
Yes
Write during RUN
Enabled
Setting change
Enabled
Transmission speed
9600 bits/s
Type
Intelligence
Model name
Model name of the unit to install
Number of points
32 points
Head X, Y
Head input/output signal number of the target unit (hexadecimal)
Setting switch
Setting item
Setting value
Switch 1 (ch1)
or
Switch 2 (ch2)
Operation Setting
Independent
Data bit length
8 bits
Parity
Odd
Stop bit length
1 bit
Sum check
Yes
Write during RUN
Allowed
Setting change
Allowed
Transmission speed
9600 bits/s
Switch 1 (ch1)
or
Switch 2 (ch2)
Communication protocol
MC protocol format 4
Switch 5
Prefix setting
0