7-11
7
E DV-90-IM
How to Use the Setup
So
ftw
a
re
(Communication Setting (Detail))
(Connect Unit: Code Reader)
Receive Data Format
RTS/CTS Protocol
• Receive Data Format
Sets the receive data format.
STX...ETX
none…CR
ESC…CR
• RTS/CTS Protocol
Sets the RTS/CTS protocol.
(
Refer to 8-5)
Input Limit
Limit Start
Limit Digits
Code Quality Notice
Quality Level
Read Error Check
Direction
Trigger Mode
• Input Limit
Sets Enable/Disable of the input digit
limit function.
When Input Limit is enabled, the Direc-
tion, Limit Start, and Limit Digits can be
specified.
(
Refer to 5-4)
• Trigger Mode
Sets the trigger mode when the code
reader is connected. (
Refer to 3-9
Note )
Hard Trigger
Soft Trigger
• Read Error Check
Sets the operation to perform when a
read error occurs.
• Code Quality Notice
Sets the output of the read quality check
function. (
Refer to 5-14)
• Quality Level
Sets the threshold of the read quality
check.
(
Refer to 5-14)